Created Nov 08, 2021 by Kai Uwe Broulik@broulik🍇Developer

Always dismiss critical battery notification

  • Overview 0
  • Commits 1
  • Changes 1

The timer isn't running when user chose "Do nothing" on critical battery

BUG: 445171 FIXED-IN: 5.23.4


Untested because on my 5.11 kernel it doesn't see AC (un)plug o.O